Data Integrator provides a delta query feature where the adapter checks for new alarms without returning all alarms each time.
Select an element in the pane.
In the right pane, click the icon to display the tab.
Use the and tabs to define the generated or custom query.
For more information, see Section 6.0, Defining Queries and Properties.
Click the tab.
To create properties for procedure results columns:
check box.
Select from the drop-down list.
To check for any delta results, specify the name of the result column in the field.
Select an element in the pane.
In the right pane, click the icon.
Click the tab.
Include the Computed Property in the stored procedure invocation.
For example, if the property using the option is HighestCustomerID, then the execute statement might look like the following:
#if ( ${query.initial} )
Execute sp_mysp 0 GETDATE()
#else
Execute sp_mysp ${query.property.HighestCustomerID} GETDATE()#end
Click the tab.
Click the radio button next to .
All alarms not in the subsequent query remain in Operations Center.
If you click , the alarms are removed and the adapter element shows only the delta alarms.